DEVELOPMENT OF BIOMEDICAL SUPERALLOYS FOR DENTAL RESTORATION AND ORTHOPEADIC TECHNIQUE OF BONES
Abstract
This paper presents on the results of research, production and applications of metals and alloys in dental and orthopeadic applic ation. The subsequent section then explains some of the most basic methods of research and production processing, and utilisation of biomedical metals and alloys. Biomedical superalloys are not only for applying in dental use, but also use for bone orthopeadics developing with promising results.Especially, Titanium has many useful features including low specific gravity, half that of nickel, excellent corrosion resistance and strength, high biocompatibility, and non-magnetic properties useful for orthopaedic application. The alloys such as Ni-Cr, Ni-Ti, Ti-Al-V, Co-Cr were investigated and resulted utilizationin this paper.
References
Tô Duy Phương, Báo cáo khoa học tổng kết đề tài “Nghiên cứu công nghệ chế tạo hợp kimnha khoa
nikencrômmolybdentitan” Viện KH&CN Việt Nam 2008-2009
Tô Duy Phương, Báo cáo khoa học tổng kết đề tài “Nghiên cứu chế tạo hợp kim NiCrMoTi làm vật
liệu chấn thương chỉnh hình nha khoa”,Viện Khoa học Vật liệu 2006
Wylie C M, Shelton R M, Fleming G J, Davenport A J.Corrosion of nickel-based dental casting
alloys [J]. Dental Materials, 2007, 23: 714-723.
Geis-Gérstorfer J, Sauer K H, PaslerK. Ion release from Ni-Cr-Mo and Co-Cr-Mo casting alloys [J].
International Journal of Prosthodontics, 1991, 4: 152-158
Goff A H L, Joiret S, Abourazzou K D. Raman investigation of crevice corrosion in Ni-Cr dental
alloys containing Be [J]. Electrochimica Acta, 1998, 43: 53-62.
Bumgardner J D, Lucass L C. Surface analysis of Ni-Cr dental alloys [J]. Dental Materials, 1993, 9:
-259.
Pan J, Geis-Gerstorfer J, Thierry D, Leygrff C. Electrochemical studies of the influence of beryllium
on corrosion resistance of Ni-25Cr-10Mo cast alloys for dental applications [J]. Journal of
Electrochemical Society, 1995, 142: 1454-1458.
Huang H H. Surface characterization of passive film on NiCr based dental casting alloys [J].
Biomaterials, 2003, 24: 1575-1582.
Liu L, Li Y, Wang F. Influence of microstructure on corrosion behaviour of a Ni-based superalloy
in 3.5wt.% NaCl [J]. Electrochimica Acta, 2007, 52: 7193-7202.
Hodgson A W E, Kurz S, Virtanen S, Fervel V, Olsson C O A, Mischler S. Passive and transpassive
behavior of CoCrMo in simulated biological solutions [J]. Electrochimica Acta, 2004, 49:
-2178.
Kocijan A, Milosev I, Pihlar B. Cobalt-based alloys for orthopedic applications studied by
electrochemical and XPS analysis [J]. Journal of Materials Science Materials in Medicine, 2004, 15:
-650.
Dee KC, Puleo DA, Bizios R. An introduction to tissue-biomaterial interactions. New York: WileyLiss 2002; pp. 53-88.
Park JB. Biomaterials science and engineering. Plenum. New York: Wiley-Liss 1984; pp. 193-233.